| Simscape™ | ![]() |
Hydraulic Sensors and Sources

The Ideal Hydraulic Flow Rate Source block represents an ideal source of hydraulic energy that is powerful enough to maintain specified flow rate at its outlet regardless of the pressure differential across the source. Block connections T and P correspond to the hydraulic inlet and outlet ports, respectively, and connection S represents a control signal port. The flow rate through the source is directly proportional to the signal at the control port S. The entire variety of Simulink signal sources can be used to generate desired flow rate variation profile.
The block positive direction is from port T to port P. This means that
the flow rate is positive if it flows from T to P. The pressure differential
is determined as
and is negative if pressure at the source
outlet is greater than pressure at its inlet. The power generated by the source
is negative if the source delivers energy to port P.

The block has no parameters.