Documentation Center

  • Trial Software
  • Product Updates

Supercapacitor

Implement generic supercapacitor model

Library

Electric Drives/Extra Sources

Description

The Supercapacitor block implements a generic model parameterized to represent most popular types of supercapacitors. The block implements the following Stern equation and Tafel equation:

VariableDescription
AInterfacial area between electrodes and electrolyte (m2)
cMolar concentration (mol m −3) equal to c = 0.86/(8NAr3)
FFaraday constant
iCurrent density (Am−2)
ifLeakage current (A)
i0Exchange current density i0 = if/A (Am−2)
kStefan-Boltzmann constant
NNumber of layers of electrodes
NAAvogadro constant
Np Number of parallel supercapacitors
NsNumber of series supercapacitors
QElectric charge (C)
RIdeal gas constant
rMolecular radius equal x2
x2Helmholtz layer length (m)
αCharge transfer coefficient, Tafel equation (0<alpha<1)
εPermittivity of material
ε0Permittivity of free space
ΔVOver potential

Dialog Box and Parameters

Parameters Tab

Rated capacitance (F)

Specify the nominal capacitance of the supercapacitor, in farad.

Equivalent DC series resistance (Ohms)

Specify the internal resistance of the supercapacitor, in ohms.

Rated voltage (V)

Specify the rated voltage of the supercapacitor, in volts. Typical rated voltage is equal to 2.7 V.

Surge voltage (V)

Specify the surge voltage or maximum voltage of the supercapacitor. Surge voltage corresponds to the supercapacitor voltage when internal electrolyte becomes gas.

Number of series capacitors

Specify the number of series capacitors to be represented.

Number of parallel capacitors

Specify the number of parallel capacitors to be represented.

Initial voltage (V)

Specify the initial voltage of the supercapacitor, in volts.

Leakage current (A)

Specify the leakage current of the supercapacitor, in amperes.

Operating temperature (celsius)

Specify the operating temperature of the supercapacitor. The nominal temperature is 25° C.

Stern-Tafel Parameters Tab

Use predetermined parameters

When this check box is selected, loads predetermined parameters of the Stern model into the mask of the block. These parameter values have been determined from experimental tests, and they can be used as default values to represent a common supercapacitor. Experimental validation of the model has shown a maximum error of 4.57% for self discharge and maximum error of 1.2% for charge and discharge when using the predetermined parameters.

When this check box is selected, the Number of layer, Molecular radius (m), Overpotential (V), Charge transfer coefficient alpha parameters appear dimmed.

Number of layers

Specify the number of layers related to the Stern model.

Molecular of radius (m)

Specify the molecular radius related to the Stern model, in meters.

Over-potential (V)

Specify the over-potential related to Tafel equation, in volts.

Charge transfer coefficient (R)

Specify the charge transfer coefficient related to Tafel equation as a value between 0 and 1.

Charge Characteristics Tab

Plot capacitor vs time

When this check box is selected, the block plots a figure containing three graphs. The first graph represents capacitance as a function of time, the second graph represents voltage as a function of time, and the third represents current as a function of time.

Charge current (A)

Specify the charge current, in ampheres, used in the plot Capacitor vs Time and shown in the third graph.

Time (s)

Specify the maximum time value of the plot, in seconds.

Inputs and Outputs

m

Outputs a vector containing measurement signals. You can demultiplex these signals using the Bus Selector block.

SignalDefinitionUnitsSymbol
1The supercapacitor currentACurrent
2The supercapacitor voltageVVoltage
3The state of charge (SOC), between 0 and 100%SOC

The SOC for a fully charged supercapacitor is 100% and for an empty supercapacitor is 0%. The SOC is calculated as:

Model Assumptions

  • Internal resistance and capacitance are assumed constant during the charge and the discharge cycles.

  • The model does not take into account temperature effect.

  • No aging effect is taken into account.

  • Charge redistribution is the same for all values of voltage.

  • The block does not model cell balancing.

  • Current through the supercapacitor is assumed to be continuous.

Example

The parallel_battery_SC_boost_converterparallel_battery_SC_boost_converter example shows a simple hybridization of a supercapacitor with a battery. The supercapacitor is connected to a buck/boost converter and the battery is connected to a boost converter. The DC bus voltage is equal to 42V. The converters are doing power management. The battery power is limited by a rate limiter block, therefore the transient power is supplied to the DC bus by the supercapacitor.

References

[1] Oldham, K. B. "A Gouy-Chapman-Stern model of the double layer at a (metal)/(ionic liquid) interface." J. Electroanalytical Chem. Vol. 613, No. 2, 2008, pp. 131–38.

[2] Xu, N., and J. Riley. "Nonlinear analysis of a classical system: The double-layer capacitor." Electrochemistry Communications. Vol. 13, No. 10, 2011, pp. 1077–81.

Was this topic helpful?